This modern range of ovens provides a combination of excellent performance and reliability. Increased power and low thermal mass encased fibre insulation ensure both fast heat up times and reduced recovery times. Reduced holding power once at set temperature, together with the insulation, makes the range economical and outer case temperatures have been significantly reduced. Both gravity and forced air circulation models are
available with a wide choice of control options allowing the most critical
performance criteria to be met. Where processes involve the liberation
of flammable vapours, a stoving and curing option is available. Also,
where processes involve large amounts of water, a moisture extraction
option is available. |
|
OVENS WITHOUT FANS | OVENS WITH FANS | |||||||
Model | PN30 | PN60 | PN120 | PN200 | PF30 | PF60 | PF120 | PF200 |
Max Temp (°C) | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 |
Chamber Dimensions(mm) height width depth |
250 330 320 |
350 392 420 |
450 492 520 |
700 592 520 |
300 292 320 |
400 392 420 |
500 492 520 |
750 592 520 |
External Dimensions(mm) height width depth |
470 665 470 |
570 765 570 |
670 865 670 |
920 965 670 |
470 665 470 |
570 765 570 |
670 865 670 |
920 965 670 |
Chamber Capacity (liters) | 27 | 58 | 115 | 215 | 28 | 66 | 128 | 230 |
Weight (Kg) | 30 | 45 | 60 | 75 | 30 | 45 | 60 | 75 |
Shelves (number supplied) (max possible) (max dist load/shelf kg) (max load kg) |
2 3 10 20 |
2 5 10 30 |
2 9 10 40 |
2 15 10 50 |
2 3 10 20 |
2 5 10 30 |
2 9 10 40 |
2 15 10 50 |
PERFORMANCE | ||||||||
Power Rating at 240 V (watts) |
750 | 1000 | 1500 | 2250 | 1000 | 1500 | 2000 | 2700 |
Holding Power* at max temp (watts) |
300 | 480 | 720 | 1160 | 350 | 600 | 800 | 1250 |
Temperature Uniformity* (at max temp as a %) |
+/-2.3 | +/-2.3 | +/-2.7 | +/-3.5 | +/-1.0 | +/-1.0 | +/-1.0 | +/-1.0 |
Temperature Stability on/off control (°C) |
+/-1.5 | +/-1.5 | +/-1.5 | +/-1.5 | +/-1.0 | +/-1.0 | +/-1.0 | +/-1.0 |
Heat Up Times* (mins) 240V 100°C 200°C 300°C |
12 26 52 |
12 26 52 |
12 26 52 |
14 29 58 |
4.5 12 25 |
4.5 12 25 |
4.5 12 25 |
5.5 14 30 |
Recovery Times* (mins) door open 60secs 240V 100°C 200°C 300°C |
2.5 5 8.5 |
2.5 5 8.5 |
2.5 5 8.5 |
3 6 10 |
1 2.5 4 |
1 2.5 4 |
1 2.5 4 |
1.5 3 5 |
Air Exchanges vol (l/h) @100°C (a) (b) |
N/A N/A |
N/A N/A |
N/A N/A |
N/A N/A |
1400 10,000 |
1400 10,000 |
1400 10,000 |
1400 10,000 |
Air Exchanges - exchanges/hour (a) (b) |
N/A N/A |
N/A N/A |
N/A N/A |
N/A N/A |
50 360 |
21 153 |
11 79 |
6 44 |
Note: A uniformity of +/-1% = +/-1°C
at 100°C. * With vents closed (a) with standard fan (b) with optional exhaust fan |