The Crowcon Xsafe is designed for easy installation and maintenance – keeps costs down. There are three junction box options designed to make replacement of sensors and sinters extremely simple. Spare sensors simply plug-in. Many spare parts are common to all Xgard models – keeps spares holding requirements to a minimum. The Xsafe is available for either wall or ceiling mounting – no need for additional brackets. The unit can accommodate M20, 1/2″ NPT or 3/4″ NPT cable glands – suits all site requirements. Accessories are available for duct mounting and sampling applications as well as remote gassing.

Find out more on our sister site Cadmus Products

Manufactured using a choice of three materials: glass reinforced nylon, highly durable aluminium with a tough polyester coating, or 316 stainless steel for ultimate corrosion resistance – designed to operate even in the harshest environments
Spray deflectors and weatherproof caps are available for use in areas subject to regular wash-downs, or offshore environments. All models have been validated to the functional safety standard IEC 61508 (SIL 1 to SIL 3).


Get a Quote
Crowcon

Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.

The Xgard range of gas detectors has been specifically designed to meet your requirements. The dangers presented by toxic and flammable gases as well as oxygen deficiency vary with each application.

Xsafe is a non-certified low cost catalytic bead type detector with 3-wire 4-20mA or mV bridge output.

Size 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches)
Weight 1kg (2.2lbs)
Enclosure material Aluminium
Ingress protection IP65
Cable entries 1 x M20, 1/2 “NPT or 3/4 NPT* on right-side
Terminations 0.5 to 2.5mm2
Sensor type Catalytic bead
Operating temperature mV: -40 to +80°C (-40 to 176°F)
mA: -40 to +55°C (-40 to 131°F)
Storage -25°C to +65°C (-13°F to +149°F)
Humidity 10 to 95% RH
Repeatability Zero drift <2% FSD (Typical)
<2% FSD per Month (Typical)
Response time T90 <15s (Typical)
OPerating voltage mA: 10-30V dc
mV: 2.0V dc
Power requirements mA: 50mA at 24V dc 1.2W
mV: 300mA (Typical)
Electrical output mA: 3- wire 4-20mA (current sink or source)
mV: 3- wire mV bridge
Typical signal: 12-15mV/ %LEL CH4
Approvals Not certified for use in hazardous environments

Safe area only

EMC compliance EN 50270
FCC Part 15
ICES- 003