The Crowcon TXgard-IS+ is a Intrinsically Safe (I.S.) toxic and oxygen gas detector with local LCD display. A very wide choice of sensors are available for use in a variety of applications. TXgard-IS+ is ATEX certified for use in Zone 0,1 or 2 hazardous areas and also UL and cUL certified for use in Division 1 or 2 hazardous areas.
Find out more on our sister site Cadmus Products
Features:
Non-intrusive calibration
Calibration can be performed locally without the need for hot work permits – minimises operational down-time
Local display and buttons enable calibration without opening the junction box
Flexible output options
4-20mA current sink – works with a wide selection of control panels
2 wire format
Rugged and reliable
Made from tough carbon loaded nylon
Ingress protection to IP65 as standard
Low cost of ownership
Non-intrusive one man calibration – easy to operate and maintain
Long life sensors – keeps interuption to on-site activity to a minimum
Simple parts replacement
Wide range of sensors
Extensive range of electrochemical sensors for toxic gases and oxygen
Size | 160 x 123 x 92mm (6.3 x 4.8 x 4.5ins) |
Weight | 0.7kg (1.5lbs) |
Ingress protection | IP65 |
Enclosure material | Junction box: Carbon loaded nylon Sensor housing: ABD Plastic |
Power | 8-32Vdc, 4-20mA loop-powered |
Cable entries | 1 x M20 or 1/2” NPT with adaptor |
Operating temperature | -20°C to +55°C (-4°F to 132°F) * |
Humidity | 15 to 90% RH non-condensing |
Display | 2-Line, 16 character LCD |
Calibration method | Via push-buttons |
Electrical output | 2 wire 4-20mA sink |
Terminals | Suitable for up to 2.5mm2 cable |
Sensor type | Electrochemical |
Repeatability | +/- 2% FSD typically |
Zero drift | +/- 2% FSD, 6 months typically |
Response time | Contact Crowcon for a full list of sensor response times |
Performance | Tested in accordance with EN60079-29-1 |
Hazardous area zones | Zone 0, 1 or 2 Division 1 or 2 (when connected via an isolation device) |
Approvals | Ex II 1 G Ex ia IIC T4 (-40°C to +65°C) Exia IIC T4 Gb Tamb -20°C to +55°C UL Class I, groups A, B, C and D |
EMC compliance | EN 50270, FCC: CFR 47 Part 15, ICES-003 |
* Figures shown exclude the sensors – Please contact Crowcon for a full list of sensor operating temperatures
Gases and Ranges
Gas | Range Available |
Ammonia (NH3) | 50, 100, 1000ppm |
Chlorine (Cl2) | 5, 10, 20ppm |
Carbon monoxide (CO) | 250, 500ppm |
Chlorine dioxide (ClO2) | 1ppm |
Hydrogen (H2) | 2000ppm, 50% LEL, 100% LEL |
Hydrogen cyanide (HCN) | 25ppm |
Hydrogen sulphide (H2S) | 25, 50, 100, 200ppm |
Hydrogen fluoride (HF) | 10ppm |
Nitrogen dioxide (NO2) | 10ppm |
Oxygen (O2) | 25% vol. |
Ozone (O3) | 1ppm |
Phosgene (COCl2) | 1ppm |
Phosphine (PH3) | 2ppm |
Sulphur dioxide (SO2) | 10, 20, 30ppm |
TXgard-IS+ Accessories
C01338 Spray deflector. For outdoor installations & protection from water sprays.
C01339 Flow adaptor, for use in sampling applications.
00027D Stainless steel duct mounting plate - for GRP junction boxes. Maximum duct airflow: 6 metres per second. Use TXgard-IS+ detector with side-entry.
C03005 Calibration adaptor
M02025 Cable gland M20 Nylon.
TXgard-IS & TXgard-IS+ Spare Sensor Assemblies
S011185 NH3 (Sensoric), 0-1000 ppm (-20C min.): for TXgard-IS, IS+
S01730 NH3 (Sensoric), 0-50 ppm (-20C min): for TXgard-IS, IS+
S01181 NH3 (Bionics), sensor assembly: for TXgard-IS
C01187 NH3 (Bionics), sensor electrolyte: for TXgard-IS
M02096 NH3 (Bionics), sensor membrane: for TXgard-IS
S01984 B2 (Sensoric): for TXgard-IS
S01872 B2 (Bionics): for TXgard-IS
491/1 B2 (Bionics) sensor electrolyte: for TXgard-IS
S01171 CO (City): for TXgard-IS, IS+
S01182 CL2 (City): for TXgard-IS, IS+ 0-20ppm only)
S011189 CL2 (Sensoric): for TXgard-IS, IS+ (0-5, 10ppm )
S01900 CLO2 (City): for TXgard-IS
S01642 ETO (City): for TXgard-IS
S01187 F2 (Bionics): for TXgard-IS
C01235 F2 (Bionics) sensor electrolyte: for TXgard-IS
M02196 F2 (Bionics) sensor membrane: for TXgard-IS
S01728 HCL (Sensoric): for TXgard-IS
S01178 HCN (City): for TXgard-IS
S01729 HCN (Sensoric): for TXgard-IS, IS+
S01983 HF (Sensoric): for TXgard-IS, IS+
S01188 HF (Bionics): for TXgard-IS
M02197 HF (Bionics) membrane: for TXgard-IS
C01236 HF (Bionics) sensor electrolyte: for TXgard-IS
S01176 H2/Hi (City 3-Series) Hi: for TXgard-IS, IS+
S01177 H2/Lo (City 7-Series) Lo: for TXgard-IS, IS+
S013000 H2 3E 4%, 0-100% LEL: for TXgard-IS+
S01170 H2S (7H sensor): for TXgard-IS, IS+
S01174 NO (City): for TXgard-IS
S01175 NO2 (City): for TXgard-IS, IS+
S01169 O2 (C/2): for TXgard-IS, IS+
S012028 O2 (7OX-V): for TXgard-IS+ 2009 onwards
S01186 O3 (City) (Citi): for TXgard-IS
S011201 O3 (Sensoric) (Sensoric): for TXgard-IS+
S01640 PH3 (City): for TXgard-IS, IS+
S011987 SiH4: for TXgard-IS
S01172 SO2: for TXgard-IS, IS+
S011226 SO2 - hydrogen immune: for TXgard-IS
S01641 VO (City): for TXgard-IS
S01343 Bayonet sensor housing for 3-pin 32mm diameter sensors: for TXgard-IS, IS+
TXgard-IS+ Spares
S01999/S Personality module for general toxic versions
S011160/S Personality module for ozone or chlorine detectors
S011161/S Personality module for hydrogen cyanide or phosgene detectors
S01997/S Personality module for oxygen detectors (1 year C/2 sensor)
S011007 Terminal PCB (Base board)
S011051 Terminal PCB (Base board)
S011050 Main/Display PCB
S012126/S Personality module for general toxic versions (Non Biased)
S012127/S Personality module for ozone or chlorine detectors (Non Biased)
S012128/S Personality module for hydrogen cyanide or phosgene detectors (Non Biased)
S011052/S Personality module for oxygen detectors (2 year 7OX-V sensor)
S011224 Terminal PCB (Base board)
S011223 Main/Display PCB
E01755 Front panel display/membrane label
M07214 Installation, Operating and Maintenance Manual
TXgard-IS+ I.S. Toxic and Oxygen Gas Detector With Display
TIP-01 carbon monoxide 0-250ppm , M20, top entry, ATEX/IECEx
TIP-02 carbon monoxide 0-500ppm , M20, top entry, ATEX/IECEx
TIP-03 chlorine 0-5ppm , M20, top entry, ATEX/IECEx
TIP-04 hydrogen sulphide 0-25ppm , M20 , top entry, ATEX/IECEx
TIP-05 hydrogen sulphide 0-50ppm , M20 , top entry, ATEX/IECEx
TIP-06 hydrogen sulphide 0-100ppm , M20 , top entry, ATEX/IECEx
TIP-07 oxygen 0-25% Vol. , M20, top entry, ATEX/IECEx
TIP-08 ozone 0-1ppm , M20, top entry, ATEX/IECEx