Detcon 100 Series Toxic Gas Sensor

Detcon 100 Series Toxic Gas Sensor

The Detcon DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.

Detcon 100 Series Toxic Gas Sensor Features:

  • XP-intrinsically Safe
  • 2 Wire Loop powered
  • Field Replaceable Electrochemical Sensor
  • Non-intrusive Magnetic Interface
  • Built-in Diagnostics
  • Fully Encapsulated ITM Electronics
  • Quick Thread Release (for sensor replacement)

Gases:

AsH3 B2H6 Br C2H4 C2H4O C2H6O C4H6 CH20 CH3OH CH4S Cl2 ClO2 CO GEH4 H2 H2S HBr HCl HCN HF N2H4 NH3 NO NO2 O2 O3 PH3 SiH4 SO2


Get a Quote
Detcon

Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.

 

The Detcon DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel (includes a transient protection terminal board). Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.

Features and Benefits:
• XP-intrinsically Safe
• Class I, Div. 1, Groups B, C & D
• 2 Wire Loop powered
• Field Replaceable Electrochemical Sensor
• Non-intrusive Magnetic Interface
• Built-in Diagnostics
• Fully Encapsulated ITM Electronics
• Electropolished 316SS Construction ITM
• Quick Thread Release (for sensor replacement)
• Integral Calibration Port

System specifications

Sensor Type
Continuous diffusion/adsorption
2-electrode electrochemical cell
Plug-in field replaceable Type

Span Drift
<5% signal loss per year (in first 2 years)

Outputs
Linear 4-20 mA DC

Electrical Classification
Explosion proof
cCSAus
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C)

Safety Approvals
cCSAus

Sensor Life/Warranty
Plug-in cell - 2 years (2 years expected life) ; Transmitter - 2 Years