Hach Lange DR300 Pocket Colorimeter

Hach Lange DR300 Pocket Colorimeter

The Titralab AT1000 Series laboratory analysis systems are one touch, automatic analysers, covering both Potentiometric Titration (AT1000 Series) and Karl Fischer volumetric Titration (KF1000 Series) with pre-set methods that can quickly deliver accurate and reliable results straight from the box, allowing anyone in the laboratory to immediately perform accurate and reproducible titrations.

  • Single Parameter go-anywhere portable photometer
  • Battery operation for a maximum of 5000 tests
  • Waterproof instrument IP67 (even better than PCII)
  • Larger, better display
  • Data connectivity. Bluetooth to Claros*

* Bluetooth connectivity currently available only in US, Canada and EU.

DR300 Pocket Colorimeters are NOT sold with chemical reagents. Reagents must be purchased separately.

Get a Quote
Hach Lange

Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.

 

Technical Data
Source Lamp Light emitting diode (LED)
Detector Silicon photodiode
Enclosure Rating IP67, waterproof at 1 m for 30 minutes
Wavelength As specified by model, ±2 nm
Spectral Bandwidth 15 nm filter bandwidth
Absorbance 0 - 2.5 Abs
Sample Cell Compatibility 1 cm (10 mL), 25 mm (10 mL)
Operating Conditions 0 - 50 °C (32 - 122 °F); 0 - 90% relative humidity (non-condensing)
Display LCD with backlight
Power Supply Four AAA alkaline batteries; approximate life is 5000 tests
Data Logger Last 50 measurements
Weight 0.25 kg (0.55 lbs.)
Dimensions (H x W x D) 34 mm x 69 mm x 157 mm
Parameters
Aluminum Range: 0.02 - 0.80 mg/L Al
Measurement Method: Aluminon
Ammonia Range: 0.01 - 0.80 mg/L NH3-N
Measurement Method: Salicylate
Bromine Range: 0.05 - 4.50 mg/L Br2, 0.2 - 10.0 mg/L Br2
Measurement Method: DPD
Chlorine, free1) + total1), 2) Range: 0.02 - 2.00 mg/L Cl2, 0.1 - 8.0 mg/L Cl2
Measurement Method: DPD
Chlorine, free1) + total1), 2), MR Range: 0.05 - 4.00 mg/L Cl2, 0.1 - 10.0 mg/L Cl2
Measurement Method: DPD
Chlorine, pH Range: 0.1 - 10.0 mg/L Cl2, 6.0 - 8.5 pH
Measurement Method: DPD, Phenol Red
Chlorine dioxide Range: 0.05 - 5.00 mg/L ClO2
Measurement Method: DPD/Glycine
Iron, Ferrover2) Range: 0.02 - 5.00 mg/L Fe
Measurement Method: Ferrover
Iron, TPTZ Range: 0.01 - 1.70 mg/L Fe
Measurement Method: TPTZ
Manganese, HR2) Range: 0.2-20.0 mg/L Mn
Measurement Method: Periodate Oxidation
Molybdenum Range: 0.02 - 3.00 mg/L Mo, 0.1 - 12.0 mg/L Mo
Measurement Method: Ternary Complex
Monochlor/Free Ammonia Range: 0.04 - 4.50 mg/L Monochloramine as CI2, 0.02 - 0.50 mg/L Free Ammonia as NH3-N
Measurement Method: Indophenol
Nitrate Range: 0.4 - 30.0 mg/L NO3-N
Measurement Method: Cadmium Reduction
Oxygen, dissolved Range: 0.2 - 10.0 mg/L O2
Measurement Method: HRDO
Ozone Range: 0.01 - 0.25 mg/L O3, 0.01 - 0.75 mg/L O3
Measurement Method: Indigo Trisulfonate
Phosphate1), 2) Range: 0.02 - 3.00 mg/L PO4
Measurement Method: Phosver 3
Zinc2) Range: 0.02 - 3.00 mg/L Zn
Measurement Method: Zincon
  • 1)Method is USEPA accepted or approved for drinking water (additional steps may be required)
  • 2)Method is USEPA accepted or approved for wastewater (additional steps may be required)
  • Note: Phenol Red colorimetric pH measurement is not accepted for regulatory reporting