Home › Laboratory › pH/Conductivity Meters › BL Series Mini Controllers
BL Series Mini Controllers
Fire retardant casing
Larger LCD
Selectable overdose protection system
External disable feature
Selectable control override
Matching pin connection
4-20 mA analog output
Traditionally, process monitoring and control has required considerable
investment in system design, equipment, maintenance and
training. With the introduction of the BL Series Mini-Controllers,
Hanna provides a solution for industries that require reliable,
efficient and affordable process monitoring and control.
The new BL Series Mini-Controllers are easy to use, durable and
provide precise monitoring and control of pH, ORP, TDS, EC,
and Resistivity.
Each Mini-Controller is 8 x 5 cm (3 x 2") in size and weighs less
than 9 oz. The compact size and simplicity of design allows for
easy installation and integration into almost any existing system.
Each model is a single set point controller designed to control the
operation of a pump, valve or mechanical device for dosing, filling
and emptying tanks and rerouting flow.
The control action of each Mini-Controller can be disabled, set to
automatic or manually operated directly from the front panel.
A selectable "Overtime" overdosing system can deactivate a valve,
pump, or other connected device if activation continues for more
than the set time, which is adjustable from 5 up to 30 minutes.
pH Mini-Controllers
Monitoring and controlling pH in water conditioning
and industrial applications is essential for water
quality and maintaining infrastructure (piping and
equipment). In the case of industrial effluent, neutralization
of acidic waste is vital for environmental
safety and public health. In industrial applications
such as boiler feed water conditioning, a higher pH
of 8.5 is necessary to prevent scaling and corrosion
of critical components. Maintaining a pH of 7.2
is fundamental for proper and efficient sanitization
in swimming pools and spas. The effectiveness of
sanitizers such as chlorine is dependent on a
controlled pH value.
ORP Mini-Controllers
ORP (Oxidation Reduction Potential) is the most
dependable and consistent indicator of the sanitizing
effectiveness of your pool, spa or treatment
water. As oxidizers such as chlorine, peroxide and
O-zone are added to water for the purpose of sanitization,
the ORP value increases, providing a clear
indication of the cleansing power of the water.
Typically, an ORP value of 650 to 700 mV at a pH
of 7.2 indicates that your water is properly treated
and all harmful bacteria are killed in less than 1 second.
ORP is also essential in chemical processing
where reducing agents are used and a negative ORP
value is an indicator of proper neutralization.
Conductivity Mini-Controllers
In water, an increase in conductivity indicates an
increase in water hardness and a decrease in purity.
Conductivity monitoring and control is essential in
reducing water hardness and maintaining water
quality. For instance, water with a conductivity
value in the range of 0-140 μS is considered "very
soft" where as water with a range of 640-840 μS
is considered "hard" water. An increase in conductivity
indicates an increase in the amount of damaging
dissolved solids (salts) present in water.
Conductivity monitoring and control is essential in
industrial applications such as feed water control,
blow down activation in cooling towers and water
management where high conductivity will cause
scaling and corrosion of piping and damage to
critical components.
|
|
TDS Mini-Controllers
TDS measurement is an important indicator of
water quality. An increase in the TDS reading
indicates an increase in the amount of dissolved
solids (salts) present in the water. TDS monitoring
and control is imperative in industrial applications
such as feed water control, blow down activation in
cooling towers and water management where high
TDS will cause scaling and corrosion of piping and
damage to critical components.
TDS measurement is also an important indicator of
the effectiveness of water conditioning since an
increase in TDS indicates an increase in water hardness
and a decrease in purity. This will affect the
quality of drinking water, feed water and rinse
water. TDS monitoring and control is crucial in
reducing water hardness and maintaining water
quality and usability.
Resistivity Mini-Controller
Resistivity, measured in MΩ (Ohm's), is the optimal
way to measure the quality of water produced by
high purity systems such as R.O systems and water
conditioning equipment. As filter systems become
less effective, the resistivity value will decrease
indicating a need for maintenance and/or replacement
of filters and critical components. Properly
functioning RO and water conditioning systems will
consistently produce water with resistivity readings
in the range of 16 to 18MΩ.
Datasheet
|
Models in this range include the BL 931700-1,
BL 932700-0,
BL 932700-1,
BL 981411-1,
BL 982411-0,
BL 982411-1,
BL 983313-0,
BL 983313-1,
BL 983314-0,
BL 983314-1,
BL 983315-0,
BL 983315-1,
BL 983317-0,
BL 983317-1,
BL 983318-0,
BL 983318-1,
BL 983319-0,
BL 983319-1,
BL 983320-0,
BL 983320-1,
BL 983321-0,
BL 983321-1,
BL 983322-0,
BL 983322-1,
BL 983324-0,
BL 983324-1,
BL 983327-0,
BL 983327-1,
BL 983329-0,
BL 983329-1,
BL-931700-0 and BL-981411-0.
They are also known as BL-931700-1,
BL-932700-0,
BL-932700-1,
BL-981411-1,
BL-982411-0,
BL-982411-1,
BL-983313-0,
BL-983313-1,
BL-983314-0,
BL-983314-1,
BL-983315-0,
BL-983315-1,
BL-983317-0,
BL-983317-1,
BL-983318-0,
BL-983318-1,
BL-983319-0,
BL-983319-1,
BL-983320-0,
BL-983320-1,
BL-983321-0,
BL-983321-1,
BL-983322-0,
BL-983322-1,
BL-983324-0,
BL-983324-1,
BL-983327-0,
BL-983327-1,
BL-983329-0,
BL-983329-1,
BL-931700-0 and BL-981411-0.
Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.
Back To Last Page
|
|