Home › Environmental › Air Particles and Velocity Instruments › Met One HIAC 9073+ Liquid Particle Counting System
Met One HIAC 9073+ Liquid Particle Counting System
Met One's HIAC 9703+ liquid particle counters are the world's best for Pharmaceutical USP <788> quality control and research applications. Highly configurable, Met One have designed the HIAC 9703+ as being both easy to use and also perfect for your liquid particle counting application requirements.
Data management has been made easy with the PharmSpec software, assuring security for 21 CFR Part 11 environments.
Industry's smallest samples - Perform a full suite of tests with just 1mL of product
Manages all your application needs - Handle a full range of sample volumes from1 mL to >1000 mL Pre-configured USP, EP, JP, and KP test routines
Eliminate uncertainty from data - Alarm notification when bubbles and/or sensor contamination has impacted particle counting results
Secure sample handling - Small vial holder ensures no expensive sample gets wasted
Easily configurable for maximum flexibility - Select a preferred flow rate and utilize interchangeable sensors from 0.5 to 600µm particle size detection
Avoid costly down time - On-site service significantly reduces down time - no shipping of your unit required. Automated notification when your unit is in need of routine service
Eliminate anxiety of data loss - Data loss recovery feature protects the results in the event of a power interruption or loss. Automatic database backup to a secure network location via PharmSpec
HIAC Particle Counting Instrument Validation Services - SOP assistance and IQ/OQ validation services Utilize HIAC expertise to get your system out of the box and commissioned
Data Sheet
Manual
|
Specifications
HIAC 9703+ Liquid Particle Counter
Weight 10.7 kg (23.6 lbs)
Dimensions 343mm W X 337mm D X 482mm H (13.5 X 13.3 X 19.0 inches)
Operating Temperature 5 to 40°C (40 to 104°F) 0 to 80% relative humidity, non-condensing
Sample Temperature 5 to 40°C (40 to 104°F)
Power 100/230 VAC, 50/60 Hz, 67 W at 115/230 VAC
Viscosity Limit <50 cP
Sample Bottle Clearance 153 mm (6.02 inches)
Volume Accuracy > 95%
Flow Rate Accuracy > 95%
Sample Flow Rate 10 to 100 ml/min; Actual flow rate for the system is determined by the sensor's flow rate with step-by-step instructions and Pass/Fail results.
Tare Volumes for Probes 0.091 ml for 81 L x 1.2 mm I.D (3.2 x 0.047 inches) 0.172 ml for 154 L x 1.2 mm I.D. (6.1 x 0.047 inches) 1.57 ml for 140 L x 6.35 mm I.D. (5.5 x 0.25 inches) - large bore
PharmSpec 3 Software - for use with the HIAC 9703+ Liquid Particle Counter
Processor Pentium® 1.0 GHz
Operating System Windows® XP with Service Pack 3 or later Windows Vista® with Service Pack 2 or later Windows 7 (32 bit)
Memory 512 MB of RAM
Hard Disk 2 GB of available hard-disk space
Drives CD drive, DVD drive, USB port or network connection is required for installation
Display Super VGA video adapter and monitor,1024 x 768 or higher resolution
Power Supply Uninterrupted power supply (UPS)
Removable Drive Removable drive for backing up data, such as a recordable CD or a network server that can back up the computer hard drive
Printer Color printer capable of printing at 300 dpi
COM Port USB port to connect to the particle counting system
Software Internet Explorer 6.0 or higher and Microsoft® Excel®, Word® or Adobe® Acrobat® (to access PharmSpec reports)
|
Met One is now known as Beckman Coulter.
Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.
Back To Last Page
|
|